100% Pass Quiz 2025 NFPA Authoritative Latest CFI-I Test Cost
BONUS!!! Download part of itPass4sure CFI-I dumps for free: https://drive.google.com/open?id=1KHyLYN3QjPYtdsqDt82zdldIMJwak8cY
itPass4sure is a reputable platform that has been providing valid, real, updated, and free Certified Fire Inspector I (CFI-1) CFI-I Exam Questions for many years. itPass4sure is now the customer's first choice and has the best reputation in the market. NFPA CFI-I Actual Dumps are created by experienced and certified professionals to provide you with everything you need to learn, prepare for, and pass the difficult NFPA CFI-I exam on your first try.
NFPA CFI-I Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Make {Useful Study Notes} With NFPA CFI-I PDF Questions
Why do we need so many certifications? One thing has to admit, more and more certifications you own, it may bring you more opportunities to obtain a better job, earn more salary. This is the reason why we need to recognize the importance of getting the test CFI-I certification. Our passing rate is 98%-100% and there is little possibility for you to fail in the exam. But if you are unfortunately to fail in the exam we will refund you in full immediately. Some people worry that if they buy our CFI-I Exam Questions they may fail in the exam and the procedure of the refund is complicated.
NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q55-Q60):
NEW QUESTION # 55
What is a system that discharges water from open sprinklers activated by a detection system called?
Answer: C
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Deluge Systems:
A deluge system is a fire sprinkler system in which all sprinklers are open, and water is discharged simultaneously when activated by a separate detection system (e.g., heat or smoke detection).
Key Characteristics of a Deluge System:
Sprinkler heads are open, with no heat-sensitive element.
The piping is not pressurized with water until the detection system activates the deluge valve.
Commonly used in high-hazard areas like aircraft hangars or flammable liquid storage facilities.
Other Options Explained:
Option A (Wet-pipe system): Pipes are filled with water, and only heat-activated sprinklers discharge water.
Option B (Dry-pipe system): Pipes contain air or nitrogen; water enters after a sprinkler activates.
Option C (Preaction system): Combines elements of dry-pipe and detection systems but does not discharge from all open sprinklers.
Summary:
A deluge system discharges water from open sprinklers activated by a detection system.
NEW QUESTION # 56
Which of the following classifications of liquids indicates a flash point at or above 200°F (93°C)?
Answer: D
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Liquid Classification by Flash Point:
Per NFPA 30 (Flammable and Combustible Liquids Code):
Class IC: Flash point below 73°F but above 100°F.
Class II: Flash point between 100°F and 140°F.
Class IIIA: Flash point between 140°F and 200°F.
Class IIIB: Flash point at or above 200°F (93°C).
Why Class IIIB Applies:
Class IIIB liquids, with higher flash points, are considered less flammable and less likely to ignite under normal conditions.
Other Options Explained:
Option A (Class IC): Flash point below 100°F.
Option B (Class II): Flash point below 140°F.
Option C (Class IIIA): Flash point below 200°F.
Summary:
A Class IIIB liquid has a flash point at or above 200°F (93°C).
NEW QUESTION # 57
When may acoustical and decorative materials such as cotton, hay, paper, straw, moss, split bamboo, and wood chips be used as decorations within an assembly occupancy?
Answer: B
Explanation:
Acoustical and decorative materials pose a significant fire hazard due to their combustibility. According to NFPA 101, Life Safety Code, Section 10.3.1, and related standards:
Such materials may only be used if they are flame-retardant treated or inherently noncombustible.
The treatment must be to the satisfaction of the Authority Having Jurisdiction (AHJ), ensuring compliance with testing requirements (e.g., NFPA 701).
Small quantities (B): Even small quantities can pose risks, so this is insufficient justification.
Third-party certification (C): While helpful, AHJ approval is still required.
Reference:
NFPA 101, Section 10.3.1: Requirements for interior finishes, decorations, and trim.
NFPA 701: Testing standards for flame retardancy of textiles and materials.
NEW QUESTION # 58
What is the classification for an occupancy used to provide overnight treatment and observation for 5 to 10 bed-ridden persons that simultaneously renders the persons incapable of self-preservation under emergency conditions?
Answer: C
Explanation:
The classification of occupancies for care facilities is defined in NFPA 101, Life Safety Code.
Limited care facility (B): This classification applies to facilities providing overnight care for 4 or more persons who are incapable of self-preservation but do not meet the requirements for a full health care occupancy.
Health care (A): Applies to hospitals and nursing homes where more intensive medical care is provided.
Residential board and care (C): Involves personal care but not medical treatment.
Ambulatory health care (D): For outpatient services where occupants are capable of self-preservation.
Reference:
NFPA 101, Section 3.3.49.4: Definitions for limited care facilities.
NEW QUESTION # 59
A high-hazard occupancy less than 200 ft² (18.6 m) in size, and with an occupant load not exceeding three, requires a second means of egress when the travel distance is greater than:
Answer: D
Explanation:
According to NFPA 101, Life Safety Code, Section 7.4.1, travel distance requirements determine when a second means of egress is necessary for small high-hazard occupancies:
For high-hazard occupancies less than 200 ft² with an occupant load of 3 or fewer, a second means of egress is required if the travel distance exceeds 20 ft (6 m).
This distance allows safe evacuation while minimizing exposure to hazardous conditions.
10 ft (A) and 15 ft (B): These distances are too restrictive based on NFPA 101.
25 ft (D): This exceeds the allowable limit.
Reference:
NFPA 101, Section 7.4.1: Means of egress requirements for small high-hazard occupancies.
NEW QUESTION # 60
......
you can pass the CFI-I exam for the first time with our help. Perhaps you still cannot believe in our CFI-I study materials. You can browser our websites to see other customers’ real comments. Almost all customers highly praise our CFI-I Exam simulation. In short, the guidance of our CFI-I practice questions will amaze you. Put down all your worries and come to purchase our CFI-I learning quiz! You won't regret for your wise choice.
CFI-I Authorized Certification: https://www.itpass4sure.com/CFI-I-practice-exam.html
BTW, DOWNLOAD part of itPass4sure CFI-I dumps from Cloud Storage: https://drive.google.com/open?id=1KHyLYN3QjPYtdsqDt82zdldIMJwak8cY