Free PDF International Code Council - High Hit-Rate Fire-Inspector-II - Reliable 67 - Fire Inspector II Exam Guide Files
In order to be able to better grasp the proposition thesis direction, the 67 - Fire Inspector II Exam study question focus on proposition which one recent theory and published, in all kinds of academic report even if update to find effective thesis points, according to the proposition of preferences and habits, ponder proposition style of topic selection, to update our Fire-Inspector-II Exam Question, to facilitate users of online learning, better fit time development hot spot.
If you are sure that you want to be better, then you must start taking some measures. Selecting Fire-Inspector-II practice prep may be your key step. If you are determined to pass the exam, our Fire-Inspector-II study materials can provide you with everything you need. You can have the Fire-Inspector-II Learning Materials, study plans and necessary supervision you need. You will have no reason to stop halfway until you get success.
>> Reliable Fire-Inspector-II Guide Files <<
Quiz 2025 Useful International Code Council Reliable Fire-Inspector-II Guide Files
As far as our Fire-Inspector-II study guide is concerned, the PDF version brings you much convenience with regard to the following advantage. The PDF version of our Fire-Inspector-II learning materials contain demo where a part of questions selected from the entire version of our Fire-Inspector-II Exam Quiz is contained. In this way, you have a general understanding of our Fire-Inspector-II actual prep exam, which must be beneficial for your choice of your suitable exam files.
International Code Council 67 - Fire Inspector II Exam Sample Questions (Q85-Q90):
NEW QUESTION # 85
The occupant load of an R-2 building's common patio area is to be calculated using the value:
Answer: D
Explanation:
The occupant load for an R-2 building's common patio area must be calculated using an occupant load factor.
The correct factor is 15 gross sq. ft. per person.
Reference to Fire Inspector Documentation:
1. 2021 International Building Code (IBC) - Table 1004.5 (Occupant Load Factor) For outdoor areas (such as patios and terraces), the applicable factor is 15 gross sq. ft. per person.
2. 2021 International Fire Code (IFC) - Section 1004.5 (Outdoor Occupant Loads) The 15 gross per person requirement is applied to common outdoor gathering areas in residential occupancies (R-2).
Detailed Explanation of Answer Choices:
Option A (Incorrect): 50 net per person applies to storage areas, not patios.
Option B (Incorrect): 11 gross per person is used for business occupancies (B), not residential patios.
Option C (Correct): 15 gross per person is the correct calculation factor for common outdoor spaces in R-2 buildings.
Option D (Incorrect): The code official does not assign occupant load values arbitrarily-they follow IBC Table 1004.5.
Thus, the correct and verified answer is: C. 15 gross per person.
NEW QUESTION # 86
The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:
Answer: B
Explanation:
Reference to Fire-Flow Requirements for Type IIB Buildings:
The International Fire Code (IFC 2021), Appendix B, Table B105.1(2) establishes the minimum fire-flow requirements for buildings based on construction type, size, and the presence of sprinkler systems.
For a 75,000 sq. ft. Type IIB (non-combustible, unprotected) building without sprinklers, the required fire- flow is 5,500 gpm for 4 hours.
Why Fire-Flow Matters:
Fire-flow ensures that sufficient water is available to control and extinguish fires in large buildings.
Type IIB buildings lack built-in fire resistance enhancements, making adequate fire-flow crucial.
Clarification of Incorrect Answer Choices:
A: 3,000 gpm for 3 hours # Incorrect
Too low for a building of this size and construction type.
B: 4,000 gpm for 4 hours # Incorrect
Below the required 5,500 gpm per IFC Appendix B.
D: 5,750 gpm for 4 hours # Incorrect
Slightly above the requirement but not the exact minimum mandated by IFC Table B105.1(2).
Conclusion:
The correct and verified answer is C (5,500 gpm for 4 hours) as per IFC Appendix B, Table B105.1(2), ensuring compliance with fire-flow standards for Type IIB buildings without sprinklers.
NEW QUESTION # 87
Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?
Answer: C
Explanation:
In Group I occupancies (such as hospitals, nursing homes, and correctional facilities), keys necessary for unlocking exit doors must be individually identifiable by both sight and touch. This ensures quick identification of keys in an emergency, especially for staff members assisting occupants with limited mobility.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 1010.1.9.9 (Identifiable Keys for Exit Doors in Group I Occupancies) IFC 1010.1.9.9 specifically states that in Group I occupancies, all keys used to unlock exit doors must be uniquely identifiable by both sight and touch.
This helps staff quickly locate and use the correct key in an emergency evacuation.
2. NFPA 101 - Life Safety Code (2021 Edition) - Section 18.2.2.2.6 (Key Identification in Institutional Occupancies) NFPA 101 mandates that keys in healthcare and correctional facilities (Group I) must be distinguishable by touch and sight for emergency use.
Detailed Explanation of Answer Choices:
Option A (Incorrect): Group A occupancies (Assembly) do not have this requirement.
Option B (Incorrect): Group E occupancies (Educational) do not have this specific key-identification mandate.
Option C (Correct): Group I occupancies (Institutional) require individually identifiable keys per IFC
1010.1.9.9.
Option D (Incorrect): Group R occupancies (Residential, such as apartments and hotels) do not have this specific requirement.
Thus, the correct and verified answer is: C. Group I occupancies.
NEW QUESTION # 88
Multiple smoke alarms installed within individual guest rooms of a hotel must comply with which of the following requirements?
Answer: A
Explanation:
Smoke alarm requirements for individual guest rooms in hotels are specified in the 2021 International Fire Code (IFC) Section 907.2.11.3 and NFPA 72 (National Fire Alarm and Signaling Code).
IFC 907.2.11.3 - Smoke Alarms in Group R-1 Occupancies (Hotels and Motels):
Requires smoke alarms in sleeping areas to be interconnected so that when one alarm is activated, it will trigger all alarms within the guest room or suite.
This ensures that occupants in different areas of the same guest room are alerted simultaneously to fire hazards.
Why Other Options Are Incorrect?
A: Their batteries must be checked every six months.
The IFC and NFPA 72 require smoke alarm batteries to be checked, but they do not mandate a six-month inspection schedule.
B: They must automatically sound a fire alarm throughout the hotel.
Smoke alarms within an individual guest room do not have to activate the entire hotel's fire alarm system.
C: They must initiate an automatic fire suppression or sprinkler system.
Smoke alarms are designed for early detection and warning, not for activating fire suppression systems.
NEW QUESTION # 89
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.
Answer: A
Explanation:
The storage of liquefied petroleum gas (LP-gas) in containers by dealers awaiting resale is regulated by the
2021 International Fire Code (IFC), Section 6109 - Storage of Portable LP-Gas Containers.
IFC 6109.11 - Storage Within Buildings Not Accessible to the Public:
"Storage of LP-gas containers in buildings that are not accessible to the public shall be limited to a maximum aggregate quantity of 2,000 pounds water capacity at one location." Why Other Options Are Incorrect?
A: 735 lb. - Too low; the maximum allowed is 2,000 lb.
B: 1,000 lb. - Incorrect; IFC allows up to 2,000 lb.
D: 2,500 lb. - Exceeds the 2,000 lb. maximum permitted storage quantity.
NEW QUESTION # 90
......
People can achieve great success without an outstanding education and that the International Code Council qualifications a successful person needs can be acquired through the study to get some professional certifications. So it cannot be denied that suitable Fire-Inspector-II actual test guide do help you a lot; thus we strongly recommend our Fire-Inspector-II Exam Questions for not only that our Fire-Inspector-II training guide is designed to different versions: PDF, Soft and APP versions, which can offer you different study methods, but also that our Fire-Inspector-II learning perp can help you pass the exam without difficulty.
Test Fire-Inspector-II Cram Pdf: https://www.prep4away.com/International-Code-Council-certification/braindumps.Fire-Inspector-II.ete.file.html
You need Exam test engine in order to study the International Code Council Fire-Inspector-II exam dumps & practice test questions, Our company is known for our high customer satisfaction in the field as we never provide Fire-Inspector-II exam dump files to people just for the profits, So they give undivided attention to Fire-Inspector-II online test materials to improve the accuracy of the real questions, International Code Council Reliable Fire-Inspector-II Guide Files You may get a promotion you have been looking forward to.
For example, this can be done in Windows Vista within the Network and Fire-Inspector-II Sharing Center, and within Windows XP in the Local Area Connection Properties dialog box, No color model is as sensitive as the human eye.
Trustworthy Reliable Fire-Inspector-II Guide Files & Guaranteed International Code Council Fire-Inspector-II Exam Success with Accurate Test Fire-Inspector-II Cram Pdf
You need Exam test engine in order to study the International Code Council Fire-Inspector-II Exam Dumps & practice test questions, Our company is known for our high customer satisfaction in the field as we never provide Fire-Inspector-II exam dump files to people just for the profits.
So they give undivided attention to Fire-Inspector-II online test materials to improve the accuracy of the real questions, You may get a promotion you have been looking forward to.
After you use it, you will have a more profound experience.